    acs scale manual

    FOR Dry Cell operation, set the power source selection switch on the lower left side of the scale to Dry Cell. Insert 4 C SIZE alkaline batteries. Do not store the scale with batteries installed if it will not be used for over 30 days to precent damage from battery corrosion. The battery charge light will illuminate whenever the scale is attached to power. SCALES usa 2005 Page 6 of 16 7 KEYBOARD FUNCTIONS 1). DISPLAY PANEL Figure 1 kg g lb oz: The symbol appears to indicate the weight unit currently in use. There are are four units selectable. The default startup unit may be selected in setup. ZERO: CHRG: STABLE: LOS: LPW: TARE: The symbol appears when scale is displaying zero. Not Used. The charge light on the front panel changes to red when battery is discharged to yellow while battery is charging, and Green when battery is charged. The symbol appears when the reading is stable. The Lack of Sample symbol appears when the sample number on the platform is not enough for accurate counting operation. The Lack of Piece Weight symbol appears when the sample unit weight is not heavy enough for accurate counting operation. The symbol appears when tare function is in effect. WEIGHT: The top display line indicates the gross or net (with the tare function activated) weight on the platform. UNIT WEIGHT: The center display line indicates the average or set unit piece weight. TOTAL: The bottom display line indicates the accumulated total number of pieces on the platform. SCALES usa 2005 Page 7 of 16 8 2). KEYBOARD Figure and.: Numeric and decimal keys.Used to clear the displayed numeric readings. SCALE OPERATION Power on: Place the scale horizontally by adjust four leveling feet at the bottom of the scale, to place the bubble at center of the level eye (Figure 3). Figure 3 Figure 4 Select the desired position of the Battery Selection to Battery or Dry Cell power as follows.

    • acs scale manual, acs price-computing scale manual, acs-z weighing scale manual, acs-c scale manual, acs system electronic scale manual pdf, acs series price computing scale manual, acs scale manual, acs scale manual, acs scale manual, acs c scale manual online.

    The scales have selectable units of kilograms, grams, pounds, and ounces. They all have stainless steel weighing platforms on an ABS base assembly. All the keypads are sealed, membrane switches and the displays are large easy to read liquid crystal type displays (LCD). The LCD s are supplied with a backlight. Features include automatic zero tracking, audible alarm for pre-set weights, automatic tare, pre-set tare and an accumulation facility that allows the count to be stored and recalled as an accumulated total. Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. Avoid unsuitable tables. The tables or floor must be rigid and not vibrate. Do not place near vibrating machinery. Avoid unstable power sources. Do not place near large users of electricity such as welding equipment or large motors. Avoid high humidity that might cause condensation. Avoid direct contact with water. Do not spray or immerse the scale in water. Avoid air movement such as from fans or opening doors. Do not place near open windows. Keep the scale clean. Do not stack material on the scale when not in use. Center the bubble in the spirit level located on the left of the scale control panel. If the scale rocks readjust the levelers. Place the platform in the locating holes on the top of the scale. Do not press with excessive force as this could damage the load cell inside. There is a protective peel-off plastic coating on the platform and on the display that may be removed if desired. For AC operation or charging of internal battery, set the power source selection switch on the lower left side of the scale to the battery position and attach the power supply cable to the connector on the bottom of the scale. Be certain that it is firmly seated and that the shoulder of the plug fits into the hole in the scale case. Plug in the power supply module. The power switch is located on the bottom right side of the scale. See Figure 2.

    NORMAL TARE: Zero the scale by pressing the ZERO key if necessary. The zero indicator will be on. Place a container on the platform, a value for its weight will be displayed. Press the TARE key to tare the scale. The weight that was displayed is stored as the tare value and that value is subtracted from the display, leaving zero on the display. As product is added only the weight of the product will be shown. The scale could be tarred a second time if another type of product was to be added to the first one. Again only the weight that is added after tarring will be displayed. When the container is removed, a negative value will be shown. If the scale was tarred just before removing the container this value is the gross weight of the container plus all product that was removed. The zero indicator will also be on because the platform is back to the same condition it was when the ZERO key was last pressed. Press the TARE key again to remove the tare weight. PRETARE: This method allows you to enter a known value for the container weight from the keypad. This is useful if all containers weigh the same, or if the container is already full but the net weight is required and the tare weight of the container is known. Remove all weight from the platform, and press the ZERO key to zero the display. Enter the value for the Pretare weight IN GRAMS! including decimal values (50.00). Using the keypad, press Tare to store the tare value. The weight will show a negative value equal to the tare. Note: If you have the scale set to operate in a unit other than grams, the weight will be converted to that unit in the top window, but the Pretare weight can only be entered in grams. Place the container on the platform. The display will then show the weight of the container minus the tare weight. Then when a full container is placed on the platform the tare value will be subtracted from the gross weight displaying only the net weight of the contents.

    SCALES usa 2005 Page 9 of 16 10 For AC operation or charging of internal battery, set the power source selection switch on the lower left side of the scale to the battery position and attach the power supply cable to the connector on the bottom of the scale. Be certain that it is firmly seated and that the shoulder of the plug fits into the hole in the scale case. Plug in the power supply module. The power switch is located on the bottom right side of the scale. FOR Dry Cell operation, set the power source selection switch on the lower left side of the scale to Dry Cell. Insert 4 C SIZE alkaline batteries. Do not store the scale with batteries installed if it will not be used for over 30 days to prevent damage from battery corrosion. Turn on the power switch at the bottom of the scale (See Figure 4). The display will show 0 9 sequentially and battery voltage value (over 5.5v) for several seconds. Then it will enter the weighing mode. The weight will display zero and the zero sign appears. ZEROING THE DISPLAY You can press the ZERO key at any time to set the zero point from which all other weighing and counting is measured, It is active within 4% of power up zero. This will usually only be necessary when the platform is empty. When the zero point is reached, the Weight display will show the indicator for zero. The scale has an automatic re-zeroing function to account for minor drifting or accumulation of material on the platform. However you may need to press ZERO to re-zero the scale if small amounts of weight are shown when the platform is empty. TARING The Tare function is used to remove the package weight, effectively setting the weight display to zero. If the item tarred is removed, a negative weight is displayed. This allows weighing or counting only the contents of the container. There are two methods to enter a tare value. Normal Tare uses the weight on the platform and Pretare uses a value input by the user.

    ACCUMULATED TOTAL COUNT When counting large quantities, it is more accurate to count in smaller batches rather than one huge batch. Up to 99 batches can be counted and added to the internal scale memory. This allows the operator to keep a running total. This can continue for up to 99 entries, or until the weight capacity is reached. 3. To observe the total stored press the TOTAL key. 4. To clear the memory press TOTAL and then QUANTITY CHECK to clear all values from memory. BATTERY OPERATION The scales can be operated from the internal rechargeable battery if desired. The battery life is approximately 70 hours. When the battery needs charging the low battery symbol will be displayed, the battery should be recharged immediately. The scale will still operate for about 10 hours after which it will automatically switch off to protect the battery. To charge the battery, simply plug the AC Adapter into the scale and the AC power outlet. The charge LED on the front panel is red when battery is discharged and changes to yellow while the battery is charging, and to green when battery is charged. The scale does not need to be turned on. The battery should be charged for 12 hours for full capacity. When the battery life becomes unacceptable then obtain a sealed lead acid replacement battery of the same type and capacity. SCALES usa 2005 Page 13 of 16 14 OPTION SETTINGS To set the optional scale technical parameters, it is necessary to enter a setup menu. This is done by entering a key combination while the scale is in the weighing mode. To enter the settings menus press and hold the CE key and then briefly press the QUANTITY CHECK key and release both keys. The parameter menu has 7 functions that can be toggled thru using the ZERO key The Weight Display will show the name of the functions and the Unit Weight Display will show the setting. To step through available settings within a parameter, press the ZERO key. SETUP TABLE 1 Weight Display FILt.

    PARTS COUNTING SETTING UNIT WEIGHT In order to count parts, it is necessary to know the average piece weight of the items to be counted. This can be done by placing a known number of the items on the weighing platform and letting the scale determine the average unit weight (Sampling), or by manually entering a known weight using the keypad. WEIGHING A SAMPLE TO DETERMINE THE UNIT WEIGHT To determine the average weight of the items to be counted it will be necessary to place a known quantity of the items on the scale and then key in the number of items being weighed. The scale will then divide SCALES usa 2005 Page 11 of 16 12 the total weight by the number of items and display the average unit (piece) weight. The unit weight will be more accurate when the number of items placed on the scale is a large value. For example, A more accurate unit weight can be measured by placing 50 parts on the scale instead of 25. Zero the scale by pressing the ZERO key. If a container is to be used, place the container on the scale and press tare as discussed earlier. Place a known quantity of items on the scale. After the weight display is stable enter the quantity of items using the numeric keys followed by SAMPLE key. As more items are added to the scale, the weight and the quantity will increase. ENTERING A KNOWN UNIT WEIGHT If the unit weight is already known then it is possible to enter that value using the keypad. When weighing in kilograms or grams the unit weight is entered in grams. When weighing in pounds the unit weight is entered in pounds. When weighing in ounces, the unit weight is entered in ounces. Enter the value of the unit weight using the numeric keys followed by pressing the UNIT WEIGHT key. Add items to the scale and the weight will be displayed as well as the quantity based upon the unit weight. PRESET COUNTING ALARM Preset Counting is a procedure that causes an beep to sound when the weight on the scale falls within a preset range.

    User Manual Congratulations on the purchase of your Class B devices have a Federal Communications STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information English Spanish Limited Five-Year Warranty Your Ear Thermometer is Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, Model 407510 Please read this user s guide before installing, setting up, and using your new weather OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Long Range Systems, Inc. 9855 Chartwell Dr., Dallas, TX 75243 1-800-437-4996. V6.21 and later Installation and User Manual UK WEA-Base User manual for load cell transmitters Version 3.2 UK Failure to follow the safety rules and other basic safety precautions OCS-XZ Series Electronic Crane Scale. User s Guide - 1 - To use this website, you must agree to our Privacy Policy, including cookie policy. How To Improve The Performance Of Electronic Scales. The scale will automatically turn off about 15 minutes after the said LED MC key to clear all accumulation memories done. V. Specifications. ACS-30. ACS-15. Price Electronic Balance Scale Acs System Electronic Scale Manual Small Scale Tile Very Low Price Acs Series Price Computing System Electronic Acs Scale. Q:5 How do I change user password in Cisco Prime Infrastructure 2.x? Q:15 Does Prime Infrastructure Supports UCS E series. Welcome to buy 30kg electronic computing scale from us with good discount, acs series price computing scale user manual ACS Series Price Computing. Hangzhou Zheben Import And Export Co.,Ltd is one of the leading China 600kg price computing scale manufacturers and suppliers, we are able to provide our.Huawei S7700 Series Smart Routing Switches for converged enterprise 40 GE ports, unified user management, CSS, SVF, and iPCA technologies.In this two-part tutorial series, learn how to design and build messaging service applications.

    Data integration at scale: OSLC and the Linked Data Platform But, when the user logs in to the AIX client, the user credentials get. ACS series Electronic Digital Price Computing Scale With LCD Display acs system electronic scale manual acs series price computing scale. After calculating a color you can modify it to generate a customized color.ACS-AP-x assistant control panels user's manual (English - pdf - Manual). ACM: Association for Computing Machinery ACS: American Chemical Society American Periodicals Series Online Chicago Manual of Style Online. Optional Step Electronic Scales. A low-end smartphone has more computing power than what was available to NASA in the 1960s. If you need scales with your specification, logo, packing, etc, please negotiate with us. All samples should be paid before shippment, and the samples price is a little higher than mass order. When the mass order placed, we can return you the samples cost, or send you more products with the shippments. Updated daily.Updated daily.A wide variety of acs weighing scale manual options are available to you, such as digital display. You can also choose from with scale tray acs weighing scale manual, as well as from battery acs weighing scale manual, and whether acs weighing scale manual is weight measuring. There are 494 suppliers who sells acs weighing scale manual on Alibaba.com, mainly located in Asia. The top countries of suppliers are China, India, and South Korea, from which the percentage of acs weighing scale manual supply is 98%, 1%, and 1% respectively. We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok We're Online! How may I help you today. Chat now Chat with us now. I am Seller Buyer Start Chat.

    Description and Settings (Shown in Unit Weight Display) ).Each mode has four grades (0-3). The higher the grade is, the higher the stability is but the slower the reaction is. For example, SEL 1 0 means the reaction of the scale is the quickest, but its stability is the lowest. SEL2 3 means the reaction of the scale is the lowest, but its stability is the highest. The display will show next menu. StAb? 2trC? SELECTION OF STABILITY. There are five stable grades(0 4). The original grade is 1. The higher the grade is, the higher the stability is. The display will show next menu.The original grade is 1. The higher the grade is, the larger the zero tracing is. The display will show next menu. SCALES usa 2005 Page 14 of 16 15 Option Settings (cont.) 2.dSP? SELECTION OF ZERO DISPLAY RANGE. The original grade is 1. The higher the range is, the larger the zero display range is. The display will show next menu. UnIt? BK lg? ACAL SELECTION OF STARTUP UNITS. This function is used for setting the default unit. The unit selected will be kept in the scale when turn on the scale each times. There are four units ( kg, g, lb and oz ) to be selected. The display will show next menu. SELECTION OF BACKLIGHT MODE There are three backlight modes ( OFF, ON and AUTO ) selectable. ON means backlight is always on, OFF means backlight is always off, and AUTO means the backlight is OFF with the scale at zero, and ON with a load on the platform. The default is in AUTO mode. The display will show next menu.The display will show next menu. SCALES usa 2005 Page 15 of 16 16 SCALES USA Warranty Information Thank you for purchasing DigiWeighPro. If you need service for your scale, please your request to our customer service center at or fax it to Also you can log on our website at and contact us through our customer service page. This warranty will cover all defective scales within their warranty period. You must provide a copy of your receipt.

    This warranty will be void if the scale has been damaged due to misuse, physical abuse, accident, unauthorized service, or other cause not arising out of defects in materials or workmanship. During the one year warranty period, if your scale fails to work properly when used under normal conditions, Scales USA will repair, or at our option, replace it without charge. The Scales USA user has to pay the shipping charge to send the defective scale with the receipt of purchasing back to us and we will pay the cost of shipping to return the repaired or replaced scale to user. There are no other charges to the consumer for warranty coverage other than the shipping cost back to the manufacturer. Our USA service center address is: Scales USA E. Dunn Rd Chattaroy, WA USA Scales USA will provide the best quality scales and customer service for our entire satisfied customers and appreciate your business. Thank you for your business. The Scales USA customer service staff. SCALES usa 2005 Page 16 of 16 Operation Manual. l RCZ-A Series User Guide Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the OWNER S MANUAL Read these instructions before use.OWNER S MANUAL Read these instructions before use.Model RH520 OWNER S MANUAL Read these instructions before use.Please read this instruction Model 407780. Introduction Owner s Manual This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. Operation Manual These full-featured, field-proven, Model 42280 The 42280 is a wall-mount, tripod Voyager Pro s Advanced Applications simplify even the Do not operate this unit in direct sunlight, in contact with Technology for the Digital World. Match UPS. GE Digital Energy. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices.

    Features include automatic zero tracking, audible alarm for pre-set weights, automatic tare, pre-set tare and an accumulation facility that allows the count to be stored and recalled as an accumulated total.TOTAL: The bottom display line indicates the accumulated total number of pieces on the platform.The weight that was displayed is stored as the tare value and that value is subtracted from the display, leaving zero on the display.When the battery life becomes unacceptable then obtain a sealed lead acid replacement battery of the same type and capacity.The display will show next menu.The display will show next menu.The Scales USA user has to pay the shipping charge to send the defective scale with the receipt of purchasing back to us and we will pay the cost of shipping to return the repaired or replaced scale to user.