    Book Descriptions:

    acs 300 manual

    These capacitors increase the ground leakage current through the ground connection to the power line and may cause some ground fault circuit breakers to trip. WARNING! All electrical installation and maintenance work on the ACS 300 should be carried out by qualified electricians. Do not attempt any work on a powered ACS 300. After switching off the power, always allow the DC bus capacitors 5 minutes to discharge before working on the AC drive, the motor or the motor wiring. It is good practice to check (with a voltage indicating instrument) that the AC drive is in fact unpowered before beginning work.The ACS 300 motor cable terminals are at a dangerously high voltage when power is applied regardless of motor operation. There can be dangerous voltages inside the ACS 300 from external control circuits when the ACS 300 AC line power is shut off. Exercise appropriate care when working with the unit. Negligence to these instructions can cause physical injury and death. WARNING! The ACS 300 may introduce electric motors, drive train mechanisms and driven machines to an extended operating range. It should be confirmed that all equipment is suitable for these conditions. Do not make any voltage tolerance tests (Hi Pot or Meggar) on any part of the ACS 300. Disconnect motor wires from the ACS 300 before making any such tests on the motor or motor wiring. Failure to follow these instructions can result in permanent damage to the ACS 300. WARNING! Certain parameter settings and external control signals may cause the ACS 300 to start up automatically after an input power failure. The motor rotational direction can be locked to forward only by using the DIR parameter. See page 64 for more details. Mechanical faults on the motor, power failure or other faults may cause stoppages. Correcting the fault may cause the motor to restart. Take all necessary precautions to ensure personnel safety and to avoid damage to equipment and property before motor restart.

    • acs 300 manual, abb acs 300 manual, brivo acs300 manual, abb drives acs 300 manual, acs 300 manual, acs 300 manual, acs 300 manual, abb acs 300 manual, brivo acs 300 manual.

    Thornton, S. and Rex, A., Modern Physics for Scientists and Engineers 3rd. CFX Setup.. direction. Please refer to the diagrams above for reference..Manual to help you. gles or face shield), gloves, boots, long-sleeved shirt orYOUR INSTRUMENT PANEL.. valet key is also for locking the glove box. Chapter 7 - Drive Parameters, lists and explains the drive parameters. Chapter 8If neglected, physical injury and death may follow, or damage may occur to the AC drive, the motor and driven equipment. The material in this chapter must be studied before attempting any work on or with the unit. Warnings and Notes This manual distinguishes two sorts of safety instructions. Warnings are used to inform of conditions which can, if proper steps are not taken, lead to a serious fault condition, physical injury and death. Notes are used when the reader is required to pay special attention or when there is additional information available on the subject. Notes are less crucial than warnings, but should not be disregarded. The text next to this symbol describes ways to avoid the danger. The text next to this symbol describes ways to avoid the danger. ACS 300 User’s Manual v Safety Instructions Notes Readers are notified of the need for special attention or additional information available on the subject with the following symbols: CAUTION. Caution emphasizes a matter in order to draw special attention to it. Note! General Safety Instructions Note gives additional information or points out more information available on the subject. These safety instructions are intended for all work on the ACS 300. WARNING! All electrical installation and maintenance work on the ACS 300 should be carried out by qualified electricians. The ACS 300 and adjoining equipment must always be properly grounded. The motor and all accessories must be grounded through ACS 300. All the ACS 300 units include capacitors connected between the main circuit and the frame.

    Chapter 2 - Mechanical Installation, describes the requirements and provides instructions for the mechanical mounting of ACS 300 and the optional keypad control panel. Chapter 3 - Power Connections, describes the requirements and provides instructions for connecting wiring for input power, output power to the motor, dynamic braking components and grounding the equipment. Chapter 4 - Control Connections, describes how ACS 300 can be controlled by the optional keypad control panel or by external control signals. Instructions are provided for connecting the external control wiring. Chapter 5 - Commissioning, includes safety precautions, start-up check list and keypad control tests. Chapter 6 - Control and Parameter Logic, describes how to use the control panel. Chapter 7 - Drive Parameters, lists and explains the drive parameters. Chapter 8 - Fault Tracing, describes ACS 300 fault indications, fault memory and how to trace faults. Chapter 9 - Technical Data, lists ACS 300 technical specifications and other useful data. Appendix A - Product Conformity in EEA, provides information regarding the installation of the ACS 300 in conformance with the requirements of the European Economic Area. 2 ACS 300 User’s Manual Chapter 1 - Overview of This Manual Limitation of Liability IN NO EVENT SHALL ABB, ITS SUPPLIERS OR SUBCONTRACTORS BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT, GUARANTEE, TORT, NEGLIGENCE, STRICT LIABILITY OR OTHERWISE, including, but not limited to loss of profits or revenue, loss of use of the Equipment or any associated equipment, cost of capital, cost of substitute equipment, facilities or services, downtime costs, delays, or claims of customers of the Purchaser or other third parties for such or other damages. ABB?

    ACS 300 User’s Manual vii Safety Instructions Disconnect Device A supply disconnecting device shall be installed in each supply, by which the electric parts of ACS 300 can be disconnected from the AC line during installation and maintenance work. The disconnecting device shall conform to the requirements of all applicable electrical codes. The supply disconnecting device shall be locked in the open position while installation and maintenance work is going on. An additional hardwired electromechanical stop circuit is required to remove AC line power from the drive if there are hazards of personnel accidently contacting the moving parts of the driven machinery or if there is any other potential hazard that requires the installation of emergency stop devices. When the drive is stopped by disconnecting power, no braking is available and the motor will coast to a stop. If emergency stop braking is required, a spring set friction brake should be used.This chapter also identifies the intended audience and lists the related documentation. The purpose of this manual is to provide you with the information necessary to install, start-up, operate and service an ACS 300 AC drive. This manual also describes features and functions of the AC drive, as well as requirements for external control connections, cabling, cable sizes and routing. Intended Audience This manual is intended for those who are responsible for installing, commissioning and servicing the ACS 300 AC drive. With the help of this manual you will be able to install, start-up operate and service the ACS 300. ACS 300 User’s Manual 1 Chapter 1 - Overview of This Manual How to Use This Manual Safety instructions are at the beginning of this manual. In this chapter the general instructions are stated and various warnings and notations are described. Chapter 1 - Introduction to This Manual, the chapter you are reading now, contains general information on the purpose and contents of this manual.

    A drip shield is provided to prevent falling dirt and dripping fluids from entering the ventilation slots at the top of the enclosure. The enclosure rated NEMA 1 with the drip shield installed. Manufacturing date is determined by unit?s serial number in the name plate. First digit shows the last figure of the year. Digits two and three tell the manufacturing week. For example 5220053 where 5 means 1995 and 22 manufacturing week and the rest of the digits are for internal use. Inspection Labels Every ACS 300 has a Pass sticker to show that it is inspected and qualified. 4 ACS 300 User’s Manual Chapter 1 - Overview of This Manual Identification Labels Type Designation TYPE CODE SERIAL NUMBER Internal number Week Year Voltage 3 - 380.480 V 1 - 200.240 V Power Wall mounted 0 - internal RFI-filter 1 - without RFI-filter Figure 1-1 Type designation of the ACS 300 frame sizes R0 and R1 (code printed on the nameplate located at the right side of the heatsink). ACS 300 User’s Manual 5 Chapter 1 - Overview of This Manual General Information About ACS 300 Overview of ACS 300 ACS 300 is a PWM AC drive using the latest technology. Product Family Concept ACS 300 refers to ACS 300 product family. There are options available besides the basic unit. For instance keypad control panel, keypad control panel remote mounting kit, serial communication adapter, braking resistor and braking chopper. Ask for related documents. The ACS 300 must always be connected to a three phase motor. Figure 1-3 ACS 300 options. 6 ACS 300 User’s Manual Chapter 1 - Overview of This Manual Type Series Table 1-1 and Table 1-2 list the principal input and output ratings for each of the various ACS 300 type designations. The frame size assignments R0, R1 and R2 are used to identify the enclosure sizes and other characteristics of the various models. Table 1-1 ACS 300 AC drive types for 50 Hz and 60 Hz supplies. ACS 300 User’s Manual X1 1 2 3 4 5 6 7 8 9 10 11 12 PTC X2 1.

    s liability on any claim whether in contract, warranty, negligence, tort, strict liability, or otherwise for any loss or damage arising out of, connected with, or resulting from the contract or the performance or breach thereof, or from the design, manufacture, sale, delivery, resale, repair, replacement, installation, technical direction of installation, inspection, operation or use of any equipment covered by or in connection therewith, shall in no case exceed the purchase price of the Equipment or part thereof or services which give rise to the Claim. All clauses of action against ABB arising out of or relating to the contract or the performance or breach hereof shall expire unless brought within one year of the time of accrual thereof. In no event, regardless of cause, shall ABB assume responsibility for or be liable for penalties or penalty clauses of any description or for indemnification of customer or others for costs, damages, or expenses each arising out of or related to the goods or services of the order. Your local distributor or ABB office may hold different guarantee details, which are specified in the sales terms, conditions, or guarantee terms. These terms are available at request. If you have any questions concerning your ABB AC drive, please contact the local distributor or ABB office. The technical data, information and specifications are valid at the time ACS 300 User’s Manual 3 Chapter 1 - Overview of This Manual of printing. The manufacturer reserves the right to modifications without prior notice. Delivery Checks Please verify that the delivery is complete and correct, when you receive the ACS 300. Verify also that the AC drive is undamaged. In the event of damage, please contact the carrier involved or the supplier. If the delivery is not in compliance with the order, please contact the supplier immediately. ACS 300 is always delivered with the dummy control panel insert installed in the cover.

    Power Wiring Requirements Power wiring includes input power wiring, motor wiring, grounding connections and dynamic braking circuit wiring (optional). Table 3-1 and Table 3-2 provide wire size and input line fuse recommendation. Figure 3-1 shows the locations of the power connection terminals. Cable clamps that are provided for use with shielded power cables can be removed if shielded power cables are not used. Refer to Appendix A - Product Conformity in EEA for information regarding the installation of the ACS 300 in conformance with the requirements of the European Economic Area including recommendations regarding the use of shielded power cables to suppress RFI emissions. ACS 300 User’s Manual 15 Chapter 3 - Power Connections Note. To avoid interfering with control signals, route the control wiring away from the power wiring. Avoid long runs of control wiring parallel with power wiring. Input Power Wiring The ACS 300 is suitable for use on a circuit capable of delivering not more than 65,000 RMS symmetrical amperes at 240 or 480 volts maximum for the 200 - 240 volt or 380 - 480 volt models respectively. Caution! The maximum permissible number of DC bus chargings per minute is four. This has to be taken in consideration when using an input power contactor. Motor Wiring The ACS 300 provides solid-state motor overload protection. Motor thermal protection is activated using the TEMP LIM parameter. If this feature is not used, the motor connected to the ACS 300 requires overload protection in accordance with the National Electric Code (U.S.A). The rapid voltage changes cause capacitive current in the motor cable. This current increases with the switching frequency and motor cable length. This phenomenon can cause substantially higher current measured by the ACS 300 than the actual motor current, and can cause overcurrent tripping. Do not exceed 300 ft.If the motor cable length exceeds 300 ft., please contact your local distributor or ABB office.

    16 ACS 300 User’s Manual Chapter 3 - Power Connections Insulation Checks Warning. Do not make any voltage tolerance tests (Hi Pot or Meggar) on any part of the ACS 300. Disconnect motor wires from the ACS 300 before making any such tests on the motor or motor wiring. Failure to follow these instructions can result in permanent damage to the ACS 300. Grounding and Ground Faults The ACS 300 must always be grounded through an grounding conductor connected to the ground terminal, PE. The grounding conductor should be the same wire size as the input power wires. Metallic conduit is not suitable for use as a grounding conductor. WARNING! Make sure that the drive is securely grounded before applying power. If the drive is not properly grounded, a dangerous voltage level can develop between the conductive parts of the drive housing and ground due to high leakage current. The ACS 300 ground fault protection guards only the AC drive itself against ground faults occurring in the motor or the motor wiring. It is NOT designed to protect personnel if they come in contact with the motor wiring. Ground fault protective devices do not necessarily operate properly with AC drives. Normally occurring high frequency ground leakage currents can cause nuisance tripping. When using such devices, check their performance while the drive is operating during commissioning. The ACS 300 should be connected only to a grounded power system. If the power system is ungrounded or grounded through a high resistance, please contact ABB for assistance. ACS 300 User’s Manual 17 Chapter 3 - Power Connections X1 R0 Models X2 AC Line Tighten connections to 9 lbs. - in. torque L R1, 200 to 240V Models Tighten connections to 9 lbs. - in. torque Braking Resistor N Motor Only. BRAKE RES U2 V2 X2 X1 Braking Motor Only. Resistor AC Line BRAKE U2 V2 W2 RES L1 L2 N X2 R1, 380 to 480V Models Braking Resistor Tighten connections to 9 lbs. - in. torque W2 X1 AC Line Motor Only.

    6 27V CONTROL BOARD I 200k 250 Analog input configured by 50k X5 I U 10M 13 14 15 16 17 18 6k8 8V2 U RO1 Max: 300Vdc 250Vac 2kVA switching RO2 2Arms cont. ACS 300 User’s Manual 9 Chapter 1 - Overview of This Manual 10 ACS 300 User’s Manual Chapter 2 - Mechanical Installation Cooling Cooling of the ACS 300 is based on natural air circulation or by fan, depending on the type. See Figure 2-1 below for power derating curves. The cooling air must be clean and free from corrosive materials. If the cooling air contains dust, clean the cooling surfaces of the unit regularly using compressed air and a brush. ACS 300 AC drives are to be used in a heated, indoor, controlled environment that is free of moisture and conductive contaminates such as condensation, carbon dust and the like. ACS 300 User’s Manual 11 Chapter 2 - Mechanical Installation Mounting Mounting the To ensure proper cooling and safe installation, check that ACS 300 the mounting surface is relatively flat and that there are no openings allowing entrance to the back of the unit. The electrical connection is made using a double ended modular phone plug that is about 1.25” long. Insert the latching end of the plug into the jack on the back of the keypad. As the control panel is set in position, insert the other end of the phone plug through the opening in the drive cover into the jack on the front of the drive. Secure the control panel in place using the screws provided. An optional mounting kit is available for mounting the control panel remotely from the drive. For example, when the drive is mounted inside a larger enclosure, the mounting kit is used to mount the control panel on the enclosure door. The mounting kit includes a cable about 10 feet (3 m) long and a gasket that is suitable for NEMA 4 sealing. Mounting instructions are provided with the kit. Note! The dummy control panel insert cannot be mounted on the ACS 300 when the Control Panel connection cable is connected. Note!

    Use only a connection cable equivalent to the one in the kit. Check the plug polarity. Pin one of the plug at one end of the cable is connected to pin 6 of the plug at the other end. The remainder of the connections are pins 2 to 5 and 3 to 4. If the cable is not correct, the control panel will be damaged. To minimize radiated RFI emissions, use a metal conduit for the control panel cable if it is not enclosed by a metal enclosure. Mounting the The optional RFI filter for frame R0 must be mounted as Optional RFI Filter close as possible the ACS 300. The metal housing of the filter must be grounded to the drive. If the drive and filter are not mounted in the same enclosure, the filter should be mounted in a small enclosure adjacent to the drive. The wir- ACS 300 User’s Manual 13 Chapter 2 - Mechanical Installation ing connecting the filter to the drive must be run in metallic conduit. Mounting the A drip shield is provided to prevent falling dirt and dripping Drip Shield fluids from entering the ventilation slots at the top of the drive enclosure. The drip shield snaps into place at the top of the enclosure. The enclosure is rated NEMA 1 only when the drip shield is installed. 14 ACS 300 User’s Manual Chapter 3 - Power Connections Line Voltage Ratings The ACS 300 product line includes models for use on 200 to 240 V and models for use on 380 to 480 V supplies. Tables 3-1 and 3-2 list the available models. WARNING! NEVER connect voltage higher than 240 V to the input power terminals of the 200 to 240 V model ACS 300 drives. Note! The Factory setting of the 400 V series ACS 300 supply voltage is 480 V. If your voltage is much lower than 480 V, for example 380 V or 400 V, you may get an undervoltage fault message when first using the ACS 300. After connecting the input power, change the value to correspond to the supply voltage.

    Serial communication interface is also available. Control Wiring AWG No. 18 or 20 multiconductor shielded cables should be used for all ACS 300 control wiring. Tighten the connections to 4.5 lbs.-in. torque. Note! The control connections of the ACS 300 are galvanically isolated from the power circuitry but not from the chassis ground. This is the factory default setting. Control circuit common can be disconnected from chassis ground by cutting the 0 ohm resistor (jumper wire) R191. Figure 4-1 shows the location of the control terminal block, X1 and the configuration switches and jumpers on the ACS 300 control card. Figure 4-2 shows the control terminal block connections and summarizes the control terminal functions. Cut to disconnect logic common from chassis ground. 22 ACS 300 User’s Manual Chapter 4 - Control Connections Figure 4-2 Control Card Connections. The time is for hysteresis and slow response of indication devices. Relay is energized when output frequency is below (F SUPERV hysteresis). Note! Parameter copying unsuccessful.Learn how we and our ad partner Google, collect and use data. Abb acs300 manual pdf, Siemens openstage 40 administration manual,Cbe style manual journal abbreviations,Siemens gigaset sl565 manual,Siemens simatic manager manual Abb Acs 300 Automotive Manual PDF Thischapter states the safety instructions which must be followed when installing, operating and servicing the ACS 300. Operating and Installation Series APU 250- 300. Trascrivo i seguenti centri reumatologici. Warmepumpen, Wohnungsluftung, Solarthermie und elektrischen Heizungen von Dimplex. Desert Tech was created to provide the most compact, accurate, and reliable precision weapon systems in the world.Reload to refresh your session. Reload to refresh your session.